30-12-00  STALL ANGLE-OF-ATTACK (AOA) SENSOR ANTI-ICE SYSTEM Back

A. System Function

The stall-AOA-sensor anti-ice system makes sure that ice does not collect on the stall-AOA-sensors.

B. System Components

The primary components of the system are:
  • Two switches
  • Four heaters

C. System Operation

The system supplies the electrical power to the heater elements of the left and the right stall-AOA-sensors.